The Schneider Electric Acti9 iCV40N A9DE7616 is a residual current circuit breaker with overcurrent protection 1P+N RCBO, 16 A, C curve and 300 mA type AC residual current sensitivity. It combines in a single device thermal-magnetic protection against overloads and short circuits with residual current protection against earth leakage currents, helping to optimize space and simplify installation in electrical panels.
With a breaking capacity of 6 kA at 230 V AC according to EN/IEC 61009-2-1, this Acti9 device is intended for single-phase distribution circuits. Its compact 36 mm width allows the thermal-magnetic and residual current functions to be combined in one unit, making individual circuit protection easier.
The Acti9 iCV40N combines two essential electrical protection functions. On the one hand, it incorporates a thermal-magnetic trip unit that protects the circuit against overloads and short circuits. On the other, it integrates residual current protection capable of detecting earth leakage currents.
This RCBO solution makes it possible to protect a circuit independently without needing to install a separate miniature circuit breaker and residual current device, reducing the number of components required inside the panel.
Reference A9DE7616 has a 1P+N configuration, with one protected pole and neutral on the left. It is designed for single-phase circuits with a rated current of 16 A and a rated operational voltage of 230 V AC at 50/60 Hz.
The circuit breaker incorporates a C tripping curve, suitable for many distribution circuits and loads that may present moderate inrush currents during startup.
The magnetic trip threshold is between 5 and 10 times the rated current. Thermal protection acts against sustained overloads, while magnetic protection provides a fast response to short circuits.
The A9DE7616 incorporates a 300 mA residual current sensitivity and type AC protection. This type of RCD is designed to detect sinusoidal alternating residual currents.
The 300 mA sensitivity is especially suitable for applications where protection against leakage currents and reduced risk associated with insulation faults are required. Additional personal protection using high-sensitivity devices should be selected in accordance with regulations and the characteristics of each circuit.
The Schneider Electric iCV40N A9DE7616 has a rated breaking capacity Icn of 6,000 A at 230 V AC in accordance with EN/IEC 61009-2-1.
Its service breaking capacity Ics also reaches 6 kA, equivalent to 100% of Icn, offering a high interruption capacity within its category.
The device includes local ON/OFF and fault status indication, making it easy to identify the circuit status directly from the front of the panel.
It also features a contact position indicator, providing additional visual information during inspection and maintenance operations.
The Acti9 iCV40N offers suitability for isolation in accordance with EN/IEC 60947-2. This feature allows the device to be used to electrically isolate the circuit within the conditions defined by the manufacturer and applicable standards.
The A9DE7616 is designed for quick mounting on a DIN rail. Its width of just 36 mm makes it easy to integrate into modular panels and saves space by combining thermal-magnetic and residual current functions in a single device.
The tunnel terminals allow connection from either the top or bottom, making wiring inside the electrical panel easier. The device also supports compatible comb busbar distribution systems.
The Schneider Electric Acti9 iCV40N is designed to provide a long service life inside the electrical panel. The manufacturer states a mechanical durability of 20,000 cycles and an electrical durability of 20,000 cycles.
The device has an IP20 protection rating according to IEC 60529. Installed inside a suitable modular enclosure, it can achieve a front protection rating of up to IP40, depending on the panel configuration.
It is designed to operate in environments with pollution degree 3 and within a wide temperature range.
The Schneider Electric Acti9 iCV40N A9DE7616 is a compact solution for protecting single-phase circuits against overloads, short circuits and earth leakage currents. Its combination of 16 A, C curve, 300 mA type AC sensitivity and 6 kA breaking capacity brings together the functions of a miniature circuit breaker and an RCD in just 36 mm of width.
Its DIN rail mounting, top or bottom connection, status indication and high durability make it a practical solution for electrical distribution panels where individual circuit protection is required in a compact format with the performance of Schneider Electric’s Acti9 range.